Customization: | Available |
---|---|
Electricity Type: | AC |
Number of Pole: | 4 |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product or Component Type | Contactor |
Device short name | LC1D258M7 |
Contactor application | Resistive load |
Utilisation category | AC-1 AC-3 AC-3e AC-4 |
Poles description | 4P |
[Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz |
[Ie] rated operational current | 32 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 220 V AC 50/60 Hz |
Pole contact composition | 2 NO + 2 NC |
Protective cover | with |
[Ith] conventional free air thermal current |
10 A (at 60 °C) for signalling circuit 40 A (at 60 °C) for power circuit |
Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 |
Rated breaking capacity | 450 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current |
240 A 40 °C - 10 s for power circuit 380 A 40 °C - 1 s for power circuit 50 A 40 °C - 10 min for power circuit 120 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit40 A 104 °F (40 °C) - 10 min for power circuit 84 A 104 °F (40 °C) - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit |
Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit |
Average impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
Power dissipation per pole | 3.2 W AC-1 |
[Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified |
Overvoltage category | III |
pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 6 kV IEC 60947 |
safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
mechanical durability | 15 Mcycles |
electrical durability | 1.4 Mcycles 40 A AC-1 at Ue <= 440 V |
Control circuit type | AC 50/60 Hz |
coil technology | Without built-in suppressor module |
Control circuit voltage limits | 0.3...0.6 Uc (-40…60 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz |
Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)) 70 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) |
Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) 7 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) |
Heat dissipation | 2…3 W at 50/60 Hz |
Operating time | 12...22 ms closing 4...19 ms opening |
Maximum operating rate | 3600 cyc/h at 60 °C |
tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver flat Ø 6 mm Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver No 2 Power circuit: 1.8 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
auxiliary contact composition | 1 NO + 1 NC |
auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
signalling circuit frequency | 25...400 Hz |
minimum switching voltage | 17 V signalling circuit |
minimum switching current | 5 mA signalling circuit |
insulation resistance | > 10 MOhm signalling circuit |
non-overlap time | 1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact |
Mounting Support | Plate;Rail |
standards | CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1 |
Product Certifications | LROS (Lloyds register of shipping);CSA;UL;GOST;DNV;CCC;GL;BV;RINA;UKCA |
IP degree of protection | IP20 front face IEC 60529 |
protective treatment | THIEC 60068-2-30 |
climatic withstand | IACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat |
permissible ambient air temperature around the device | -40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating |
operating altitude | 0...9842.52 ft (0...3000 m) |
fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
flame retardance | V1 conforming to UL 94 |
mechanical robustness | Vibrations contactor open 2 Gn;5...300 Hz);Vibrations contactor closed 4 Gn;5...300 Hz);Shocks contactor open 10 Gn for 11 ms);Shocks contactor closed 15 Gn for 11 ms) |
Height*Width*Depth | 3.6 in (91 mm)x1.8 in (45 mm)x3.9 in (99 mm) |
Net Weight | 0.937 lb(US) (0.425 kg) |
Category | 22355-CTR;TESYS D;OPEN;9-38A DC |
Discount Schedule | I12 |
GTIN | 3389110353075 |
Returnability | Yes |
Country of origin | China |
Unit Type of Package 1 | PCE |
Number of Units in Package | 50PCS/CTN |
Warranty | 18 months |